chemoilindia.com

Breather Valves , Flame Arrestors and
Emergency Vent

Pressure Vacuum Relief Valves(Breather Valves)

7

STANDARD SPECIFICATIONS

·        Using Elmac’s proprietary software, the required flow area and the diameter of the Pressure Vacuum Relief Valve required to the relieve the normal venting requirements.
·        Methods of Valve Sizing as per API-2000 – Co-efficient of discharge method / Flow curve Method
·        Our unique seal design offers ultra tight low leakage, reducing product losses, exceeding the requirements in API 2000 & ISO 28300
·        Minimum requirement is < 1SCFH at 75% of setting according to API 2000 (7th edition) & ISO 28300
·        High flow capacities – Skirted pallet for improved full lift performance
·        Low leakage rates – Air cushion knife edge design seat
Make : ELMAC ENVISAFE
 

End-Of-Line Flame Arrestors

8

STANDARD SPECIFICATIONS

End of Line Deflagration Arresters

·        Size Range 15mm (3/8”) – 600mm (24”)
·        Explosion Group IIA, IIB1, IIB2, IIB3, & IIC
·        Operating Temperature upto +150°C
·        Short-time burn capability
·        E-Flow™  element design – uses less material and offers a greater free area to the flow
Make : ELMAC ENVISAFE

Inline Flame Arrestors

9

STANDARD SPECIFICATIONS

In-line Unstable Detonation Arresters

·        Size Range 15mm (3/8”) -300mm (12”)
·        Explosion Group IIA, IIB1, IIB2 & IIB3
·        Operating Temperature up to +150°C
·        Short-time burn capability
·        E-Flow™ element design – uses less material and offers a greater free area to the flow

Inline Deflagration Arresters

·        Size range 15mm (3/8”) – 600mm (24”)
·        Explosion Group IIA, IIB1, IIB2, IIB3, & IIC
·        Operating temperature up to +150°C
·        Short-time burn capability
·        E-Flow™ element design – uses less material and
offers a greater free area to the flow
·        Ports for pressure and temperature ports
 
Make : ELMAC ENVISAFE

Emergency Relief Vents

10

STANDARD SPECIFICATIONS

·        Anti-fouling self-draining element
·        Significantly reduces contamination
·        Prevents ingress of rain and dirt
·        Reduces maintenance
·        Extends service life
·        Sizes up to 3″ (80mm)
·        Carbon steel, stainless steel, aluminium
·        10” NB (DN250) to 24” NB (DN600)
·        +8mbarg to +75mbarg
·        Weight loaded construction
·        Designed to API 2000/ISO 28300
·        ATEX Directive 94/9/EC compliant
·        Pressure only, vacuum only, combined options available  
Make : ELMAC ENVISAFE
 

We’re energized by problems! Let us reliably solve yours.